Compare Products
Hide
VS
Models
Series
Highlight Features
M7800C-8SFG-XB
M7800C-8SFX-XB
1+1 hot standby ensures nonstop switch services.
Two flash chips for storing boot software achieve hardware-level boot redundancy, avoiding switch boot failures due to a flash chip fault.
1+1 hot standby ensures nonstop switch services.
Two axial flow fans for factory delivery support 256-level speed regulation and precise temperature control, reducing energy consumption and noise.
Hardware Specifications |
RG-S7805C |
RG-S7808C |
RG-S7810C-X |
||
Interface Specifications |
|||||
Power module |
2 |
4 |
4 |
||
Supervisor module slot |
2 |
2 |
2 |
||
Line card slot |
3 |
6 |
8 |
||
Switch fabric module slot |
- |
- |
4 |
||
System Specifications |
|||||
Switching Capacity |
6 Tbps |
12 Tbps |
19.2 Tbps |
||
Packet Forwarding Rate |
4500 Mpps |
9000 Mpps |
14300 Mpps |
||
MAC address |
● M7800C-8SFX-XB: 256000 ● M7800C-8SFG-XB: 256000 ● XA card: 96000 ● XB card: 256000 |
||||
ARP table |
● M7800C-8SFX-XB: 9600 ● M7800C-8SFG-XB: 9600 ● XA card: 4000 ● XB card: 9600 |
||||
Number of IPv4 unicast routes |
● M7800C-8SFX-XB: 350000 (shared with IPv4 routes) ● M7800C-8SFG-XB:350000 (shared with IPv4 routes) ● XA card:64000 (shared with IPv4 routes) ● XB card: 350000 (shared with IPv4 routes) |
||||
Number of IPv4 multicast routes |
4000 |
||||
Number of IPv6 unicast routes |
● M7800C-8SFX-XB: 65000 (shared with IPv4 routes) ● M7800C-8SFG-XB:15000 (shared with IPv4 routes) ● XA card: 65000 (shared with IPv4 routes) ● XB card: 65000 (shared with IPv4 routes) |
||||
Number of IPv6 multicast routes |
2000 |
||||
Number of ACEs |
● Ingress M7800C-8SFX-XB: 2800 M7800C-8SFG-XB: 2800 XA card: 7000 XB card: 2800 ● Egress M7800C-8SFX-XB: 4000 M7800C-8SFG-XB: 4000 XA card: 1500 XB card: 4000 |
||||
Number of VSU members |
2 |
2 |
2 |
||
Dimensions and Weight |
|||||
Dimensions (W x D x H) |
442 mm × 451 mm × 175 mm (17.40 in. x 17.76 in. x 6.89 in.) |
442 mm × 465 mm × 441.7 mm (17.40 in. x 18.31 in. x 17.39 in.) |
442.5 mm × 560 mm × 442 mm (17.42 in. x 22.05 in. x 17.40 in.) |
||
Weight (empty chassis and fan modules) |
32.35 kg |
35.6 kg |
43.55 kg |
||
Rack Size |
4 RU |
10 RU |
10 RU |
||
CPU and Storage |
|||||
CPU |
2.2 GHz quad-core processor |
2.2 GHz quad-core processor |
2.2 GHz quad-core processor |
||
Storage |
Flash Memory:8 GB SDRAM:DDR4 4 GB |
Flash Memory:8 GB SDRAM:DDR4 4 GB |
Flash Memory:8 GB SDRAM:DDR4 4 GB |
||
Power Supply and Consumption |
|||||
Max. Output Power |
● RG-PA300I-F: 90 V AC to 180 V AC; Power: 300 W 180 V AC to 264 V AC; Power: 300 W ● RG-PA460I-F: 90 V AC to 180 V AC; Power: 460 W 180 V AC to 264 V AC; Power: 460 W ● RG-PA1000I-F: 90 V AC to 176 V AC; Power: 800 W 176 V AC to 264 V AC; Power: 1000 W |
● RG-PA600I-F: 90 V AC to 180 V AC; Power: 600 W 180 V AC to 264 V AC; Power: 600 W ● RG-PA1600I-F: 90 V AC to 180 V AC; Power: 1200 W 180 V AC to 264 V AC; Power: 1600 W |
● RG-PA1600I: 90 V AC to 180 V AC; Power: 1200 W 180 V AC to 264 V AC; Power: 1600 W ● RG-PA600I: 90 V AC to 180 V AC; Power: 600 W 180 V AC to 264 V AC; Power: 600 W ● RG-PD600I: –40 V DC to –75 V DC; Power: 600 W ● RG-PA1600I-PL: 90 V AC to 176 V AC; Power: 1200 W 176 V AC to 264 V AC; Power: 1600 W |
||
Maximum output power |
● M7805C-CM-X:< 40 W ● M7800C-12CQ-XB:< 240 W ● M7800C-24GT8SFP8XS-XA:< 95 W ● M7800C-32XS-XA:< 149 W ● M7800C-48XT-P-XB:< 300 W ● M7800C-48GT4XS-XA:< 85 W ● M7800C-48SFP4XS-XA:< 117 W ● M7800C-52XS-XB:< 250 W ● M7800C-8SFG-XB:< 250 W ● M7800C-8SFX-XB:< 250 W |
● M7808C-CM-X:< 62 W ● M7800C-12CQ-XB:< 240 W ● M7800C-24GT8SFP8XS-XA:< 95 W ● M7800C-32XS-XA:< 149 W ● M7800C-48XT-P-XB:< 300 W ● M7800C-48GT4XS-XA:< 85 W ● M7800C-48SFP4XS-XA:< 117 W ● M7800C-52XS-XB:< 250 W ● M7800C-8SFG-XB:< 250 W ● M7800C-8SFX-XB:< 250 W |
● M7810C-CM-X:< 60 W ● M7800C-12CQ-XB:< 240 W ● M7800C-24GT8SFP8XS-XA:< 95 W ● M7800C-32XS-XA:< 149 W ● M7800C-48XT-P-XB:< 300 W ● M7800C-48GT4XS-XA:< 85 W ● M7800C-48SFP4XS-XA:< 117 W ● M7800C-52XS-XB:< 250 W ● M7800C-8SFG-XB:< 250 W ● M7800C-8SFX-XB:< 250 W ● M7810C-FE-X I:< 50 W ● M7810C-FE-X II:< 160 W |
||
Environment and Reliability |
|||||
MTBF |
> 200,000 hours |
||||
Primary Airflow |
● Supervisor module: air intake from the right and exhaust from back ● Service module: air intake from the right and exhaust from back ● System power module: drawing air outward with built-in fans, air intake from the front panel and exhaust from back |
● Supervisor module /Service module: air intake from the right and exhaust from back, drawing air outward to form convection for heat dissipation ● System power module: air intake from the front panel and exhaust from back, drawing air inward to form convection for heat dissipation |
● Line card: air intake from the side and exhaust from back ● Supervisor module/Switch fabric module: air intake from the front panel and exhaust from back |
||
Operating Temperature |
0°C to 50°C (32°F to 122°F) |
||||
Storage Temperature |
–40°C to +70°C (–40°F to +158°F) |
||||
Operating Humidity |
10% to 90% RH (non-condensing) |
||||
Storage Humidity |
5% to 95% RH |
||||
Operating Altitude |
–500 m to +5000 m (–1,640.41 ft. to +16,404.20 ft.) |
||||
Surge Protection of Communication Ports |
6 kV |
Software Specifications |
RG-S7805C |
RG-S7808C |
RG-S7810C-X |
Ethernet switching |
Jumbo frame (maximum length: 9,216 bytes) |
||
802.3az EEE |
|||
Maximum number of VLANs that can be created: 4,094 |
|||
Voice VLAN |
|||
GVRP |
|||
IP subnet-based VLAN |
|||
MAC VLAN |
|||
Port-based VLAN |
|||
Private VLAN |
|||
protocol-based VLAN |
|||
Super-VLAN |
|||
Basic QinQ and selective QinQ |
|||
STP (IEEE 802.1.d) |
|||
RSTP (IEEE 802.1w) |
|||
MSTP (IEEE 802.1s) |
|||
ERPS (G.8032) |
|||
LLDP/LLDP-MED |
|||
Device Virtualization |
VSU |
||
SDN |
OpenFlow 1.3 NETCONF |
||
IP service |
Static and dynamic ARP |
||
DHCP client |
|||
DHCP relay |
|||
DHCP server |
|||
DHCP snooping |
|||
DNS |
|||
DHCPv6 client |
|||
DHCPv6 relay |
|||
DHCPv6 snooping |
|||
Neighbor Discovery (ND) and ND snooping |
|||
FTP Server |
|||
FTP Client |
|||
NTP server |
|||
NTP Client |
|||
SNTP Client |
|||
TFTP Client |
|||
TFTP Server |
|||
IP routing |
Static routing |
||
BGP4 |
|||
BGP4+ |
|||
IS-ISv4 |
|||
IS-ISv6 |
|||
OSPFv2 |
|||
OSPFv3 |
|||
RIP |
|||
RIPng |
|||
GR |
|||
Routing Policy |
|||
ECMP |
|||
IPv4/IPv6 VRF |
|||
Policy-based routing (PBR) |
|||
Multicast |
IGMP v1/v2/v3 |
||
IGMP snooping v1/v2 |
|||
IGMP proxy |
|||
IGMP fast leave |
|||
PIM-DM |
|||
PIM-SM |
|||
PIM-SSM for IPv4 and IPv6 |
|||
MSDP to achieve inter-domain multicast |
|||
MLDv1 and MLDv2 |
|||
Multicast static routing |
|||
MLD v1/v2 snooping |
|||
PIM-SMv6 |
|||
Multicast source IP address check |
|||
Multicast source port check |
|||
MPLS |
MPLS L3VPN |
||
MPLS 6VPE |
|||
MPLS IPv6 |
|||
MPLS forwarding |
|||
LDP |
|||
LSP |
|||
VXLAN |
VXLAN Layer 2 bridge |
||
VXLAN Layer 3 gateway |
|||
EVPN VXLAN |
|||
ACL and QoS
|
Standard IP ACL |
||
extended IP ACL |
|||
extended MAC ACL |
|||
Layer 2 and Layer 3 port ACL |
|||
VLAN ACL |
|||
Expert-level ACL |
|||
ACL 80 |
|||
IPv6 ACL |
|||
Applying ACLs globally |
|||
ACL COUNTER |
|||
ACL LOGGING |
|||
ACL REMARK |
|||
802.1P |
|||
SP |
|||
WRR |
|||
SP+WFR |
|||
other queue scheduling mechanisms |
|||
RED/WRED |
|||
Rate limiting based on the inbound or outbound interface |
|||
MPLS QOS |
|||
Reliability |
1+1 redundancy for supervisor modules |
1+1 redundancy for supervisor modules |
|
Hot swapping of all components |
N+M redundancy for power supply |
||
- |
1+1 fan redundancy |
||
- |
Hot swapping of all components |
||
Hot patching function for online patch upgrade |
|||
GR |
|||
BFD |
|||
VRRP |
|||
VRRP+ |
|||
Faulty optical port isolation |
|||
Dual physical chips for boot systems |
|||
Security |
NFPP |
||
CPP |
|||
DAI |
|||
port security |
|||
IP source guard |
|||
802.1X authentication |
|||
MAC address-based authentication |
|||
Portal authentication |
|||
RADIUS |
|||
TACACS+ login authentication |
|||
uRPF |
|||
SSHv2 |
|||
IPv6 SAVI |
|||
Login authentication and password security |
|||
providing encrypted security channels for user login |
|||
Unknown multicast packets are not sent to the CPU, and unknown unicast packets can be suppressed. |
|||
NMS and maintenance |
Console/AUX Modem/Telnet/SSH2.0 CLI configuration |
||
File upload and download management using FTP, TFTP, and Xmodem |
|||
SNMP V1/V2c/V3 |
|||
RMON |
|||
CWMP |
|||
GRPC |
|||
Fault alarm and auto-recovery |
|||
System operation logging |
|||
sFlow |
|||
SPAN |
|||
RSPAN |
|||
ERSPAN |
|||
VLAN mirroring |
|||
Web-based NMS |
|||
Energy-Saving Design |
IEEE 802.3az Energy Efficient Ethernet |
Model |
Description |
RG-S7810C-X |
RG-S7810C-X switch, which can accommodate eight line cards, two supervisor modules, and four switch fabric modules |
S7808C |
RG-S7808C switch, which can accommodate six line cards and two supervisor modules. When the M7808C-CM-X supervisor module is used, you can select line cards of the RG-S7800C-X series. |
S7805C |
RG-S7805C switch, which can accommodate six line cards and two supervisor modules. When the M7805C-CM-X supervisor module is used, you can select line cards of the RG-S7800C-X series. |
M7810C-CM-X |
RG-S7810C-X high-performance supervisor module |
M7805C-CM-X |
RG-S7805C high-performance supervisor module |
M7808C-CM-X |
RG-S7808C high-performance supervisor module |
Notes:
Model |
Description |
RG-PA300I-F |
S7805C power module (AC, 300 W, 10 A) |
RG-PA460I-F |
S7805C power module (available for redundancy, AC, 460 W, 10 A) |
RG-PA600I-F |
S7808C power module (available for redundancy, AC, 600 W, 10 A) |
RG-PA1000I-F |
S7805C Power module (support redundancy, AC, 1000W,10 A) |
RG-PA1600I-F |
S7808C power module (available for redundancy, AC, 1600 W, 16 A) |
RG-PA1600I-PL |
Common PoE power module (available for redundancy, AC, 1600 W, 16 A) |
RG-PA600I |
S7810C-X power module (available for redundancy, AC, 600 W, 10 A) |
RG-PD600I |
S7810C-X power module (available for redundancy, DC, 600 W, 20 A) |
RG-PA1600I |
S7810C-X power module (available for redundancy, AC, 1600 W, 16 A) |
M78-PSE-X |
Common PoE power chassis, used together with RG-PA1600I-PL |
Model |
Description |
M7810C-FE-X I |
RG-S7810C-X 1st-generation switch fabric module |
M7810C-FE-X II |
RG-S7810C-X 2nd-generation switch fabric module |
Model |
Description |
M7800C-32XS-XA |
32 x 10GE optical ports (SFP+ and LC connector) |
M7800C-24GT8SFP8XS-XA |
24 x GE electrical ports (RJ45), 8 x GE optical ports (SFP and LC connector), and 8 x 10GE optical ports (SFP+ and LC connector) |
M7800C-48GT4XS-XA |
48 x GE electrical ports (RJ45) and 4 x 10GE optical ports (SFP+ and LC connector) |
M7800C-48SFP4XS-XA |
48 x GE optical ports (SFP and LC connector) and 4 x 10GE optical ports (SFP+ and LC connector) |
M7800C-52XS-XB |
52 x 10GE optical ports (SFP+ and LC connector) |
M7800C-12CQ-XB |
12 x 100GE/40GE optical ports (QSFP+ and MPO/LC connector) |
M7800C-48XT-P-XB |
48 x 100M/GE/2.5GE/5GE/10GE electrical ports (RJ45 and PoE/PoE+) |
M7800C-8SFG-XB |
CWDM line card for RG-S7800C-X series switches, supporting eight SFG GE ports |
M7800C-8SFX-XB |
CWDM line card for RG-S7800C-X series core switches, supporting eight SFX 10GE ports with each port backward compatible with the Gigabit rate |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Contactați-ne
How can we help you?